VA110 user guide

VA110 is an integrated temperature station is a real-time body temperature measurement equipment. VA110 uses Atomrock Edge Computing technology, temperature sensor, integrated with dual lens frontal camera, LED light and an 8″ screen. It has the following components:

  • VA110 integrated system
  • AC adapter
  • Desktop stand or floor stand (optional)

Cloud Mode

VA110 factory default has no license enabled, so it is in cloud mode that license can be applied with the central management design. Which will connect to AtomCloud automatically and waiting for next step activation.

Please refer to cloud temperature station section for adding the VA110 into the AtomCloud's enterprise management site.

Stand-alone Mode

VA110 allow user to convert from cloud mode to stand-alone mode by entering proper license locally. System require to connect to Internet and activate the stand-alone license with verification from AtomCloud. Once the stand-alone license is accepted with an expiration date, system will no longer require Internet or external connection.

NOTE: Please consult with reseller‘s specialist for conversion from cloud mode to stand-alone mode. Conversion may not be possible depending on software configuration.

Licensing

  • CLOUD: VA110 requires valid Cloud Connection license (CC-VA110-1YR) to connect to cloud.
    • Facial search and photo search function can be enabled after adding LIC-VAS-FS-VA110 or LIC-VAS-PTOS-VA110 license.
    • Cloud recording and cloud vault function can be enabled after adding LIC-CR or LIC-ER series of license.
    • All licenses needs to be annually renewed except per-use cloud usage license.
  • STAND ALONE version: Temperature station requires LIC-VAS-TEMP-SA to be enabled.
    • Stand-alone VA110 is preloaded with facial search or photo search license on v3.3 or above version. Pervious version please inquire your local account executives for the upgrade and license enable.

Temperature measuring process

The system become active when there is a front facing human face detected within 1.5 meter from the screen. Once there is a valid face inside of the detection area, system will select the best position in combining the thermo-matrix detection to come up with the body temperature. Once the highest temperature is registered, it will continue to measure and make adjustment until the face leaves the area; or when there is a new event starts (new face enter the measuring area). The detailed events as below:

  • SYSTEM READY: When face detected anywhere in the screen, system will change approach LED level light level according to the configuration.
  • EVENT STARTS: When face is approximately within 1.5 meter and facing the device.
    Response: Display “CLOSER” text and audio
  • SUCCESS MEASUREMENT: When condition is met, and temp is 35.8°C+ (the value is adjustable) then display the highest measuring result, user access search result based on face AI and/or QR code. Temperature measurement continues to update the highest temperature until the event ends.
  • EVENT ENDS SUCCESS MEASUREMENT: When face leaves the measuring area for more than 0.8 second. The screen will continue to display the result for 10 seconds, then return to system stand-by mode if no new event starts.
  • ENENT ENDS NO MEASUREMENT: When face leaves the measuring area, the screen will return to system stand-by mode after 30 seconds.

Stand-alone Setup Menu and Features

Enter to setup menu:

In order to enter the setup mode, the device must be in the “stand alone” mode with proper license activated.

USB keyboard: Connect the USB keyboard and press Ctrl key then R key together, the system will prompt to enter text. Please type in “setup” to enter the local setup screen.

Touch screen:

  1. Touch and hold the upper left corner of the screen
  2. Continue to hold, and move to the upper right corner of the screen, you will see the grey square box appear on the upper right corner.
  3. Continue to hold, and move to the lower left of the screen, you will see the green square box appear on the lower right corner.
  4. Hold for 5 seconds then release the touch.

User then can use the touch screen and USB keyboard to operate the setup mode.

Users have access to both USB 2.0 port on the system for USB keyboard and USB drive, which accepting exFAT, FAT32, and NTFS format up to 64GB size. The USB drive can be used for record export, file upload, system upgrade and other file transfer related activities.

Setup menus consist of the following areas:

  • Display setup – configure device display and operation features such as language, sound, LED illumination level.
  • Temperature AI setup – configure temperature sensing AI parameters.
  • Device setup – display and configure device setting including firmware upgrade via AtomCloud or USB, adjust system time, upgrade system, reset to factory default, or covert stand-alone mode to cloud mode (connect to cloud is required for this function).
  • WARNING: Please consult with reseller's specialist before making the mode change.

    NOTE: change system time is for adjust the clock error, which only works when system is not connected to Internet. When system is connected to Internet, NTP will be used to sync the clock.

  • External control – configure external connections via relay.
  • Records – display or export the local records
  • User management – manages face AI user data and company hierarchy.
  • You can register new user and enter the information about the user from the screen. Or directly from the temperature record search result by using “+” mark. When add new user, please place the face photo image in the USB's “/images” directory and select it in order to enable Face AI function.

    Face AI users can be registered in bulk via CSV and face photos. When upload via CSV and photo file, please use USB drive and place the users in the root directory's “user.csv” file, and the photos in the “/user_snapshot” directory. Please see the sample below.

    Example of user.csv file

    user_name,register_id,hierarchy,status,filename1,filename2,enable_qr_code,qr_code,notes

    John_Gates,12345,US|SEA|Engineer,1,john-gates-image.jpg,,1,12345qr,

    須木花子,12346,日本|開発部,1,images_path/12346-pic.jpg,,1,qrcode12346,note here

    山田伊次郎,12348,日本|人事部,1,images_path2/subfolder/photo-12348.jpg,,1,12348character,new hire 2022

    Abby_Enmore,13,US|LA|Sales,1,Abby_0001.jpg,,0,ASGDFWEFDGA,

    Elan Muni,15,Japan|Tokyo|Management,1,Abdel_Madi_Shabneh_0001.jpg,,0,sampleqrcode,VP Engineering

    Wasabi Space,17,EU|London|Management,1,WS_0002.jpg,,0,mustbeunique,VP Sales

    Barbie,27,APAC|Tokyo|Marketing,1,Barbie_0001.jpg,,0,QR_27,Contractor

    Denny,28,APAC|Singapore|Engineering,1,Denny_0001.jpg,,0,QR_28,Contractor

    System also allows export of the Face AI user and import to another VA110 device.

    IMPORTANT:

    1. If user is placing the file within a directory under “/user_snapshot”, please use “/” or “\” to separate directory instead of “¥”. For example: under Windows file system, “E:¥user_snapshot¥tokyo¥user1.jpg” where E: is the USB drive mapping, should be “tokyo/user1.jpg” or “tokyo\user1.jpg”in the CSV’s filename1 and filename2 column.
    2. By importing Face AI user data into another device, the target device’s existing Face AI users will be deleted.
    3. The maximum registered total photo images is 1,000.
    4. Please use CSV UTF-8 (comma delimited format).  If you use Excel to edit CSV file, you can select this format in “Save As …” option.
    5. First line of the CSV is title and will not be processed. Please use "user_name,register_id,hierarchy,status,filename1,filename2,enable_qr_code,qr_code,notes" for the first line.
  • Access control – manages access control options

 

External Connection

USB 2.0

There are two USB 2.0 port connects to the system: HOST USB and USB-OTG port. Both USB port serve as external connection to USB keyboard and USB drive.

Relay

VA110 uses NEC Conventional relay, EA2 series, which complies with 1500 V surge-voltage requirement of FCC part 68 by the unique structure and the efficient magnetic circuit design, also is UL recognized (E73266) and CAS certified (LR46266) relay module.

Switch mode: 2-pin connections, ON, COM for single pole non-voltage switching function. Software control for the NC (Normal Open) ON-COM behavior can be configured based on the temperature AI event trigger.

  • Max switch voltage: DC 12 V
  • Max carry current: 0.8 A
  • External connection cable: 0.75mm² (or 20 AWG)
Wiegand control

There is a Wiegand connection capability reserved for most of the access control need. 4-pin connection to Weigand input on the remote device (cable marked Weigand Input), has D0-IN, D1-IN, 5V, GND. 3-pin connection to Weigand output on the remote device (cable marked Weigand Output), has D0-OUT, D1-OUT, GND.

RS-485

There is a 2-wire (twisted-pair) RS485’s A/B connection capability reserved for external control, which function is defined by software.

RS-232

There is a 3-wire (TX/RX/GND) RS-232 connection capability reserved for serial data transmission to/from the system. The RS-232 connection is used for data transmission only, baud rate is set for 115200, 8N1.

Connection type

Relay, Weigand, RS-485 and RS-232 can be connected by 3.81mm pitch terminal block. Please see example on the right.

Physical and Environment

Placement of the VA110 integrated system:

  • Temperature sensor position aims at average tester’s forehead.  For example, when average test’s height is 170 cm, the mounting height will be 165 cm.
  • Distance between tester’s forehead and sensor lens should be between 25 cm to 80 cm.  When tester is at 50 cm distance, the face should position at middle of the marked area on the screen with the same size as the marked head size.

The temperature sensing station is designed for indoor use in a controlled environment temperature. The installation environment must meet following criteria:

  • Device storage temperature -20°C to 70°C.
  • System operating temperature 0°C to 50°C.
  • Temperature body sensing range optimized between 10°C to 60°C.
  • Temperature body sensing suggested environment temperature between 15°C to 35°C.
  • Device measures surface temperature of the skin – instruct users to expose the forehead in order to get correct reading. Mask, sunglasses, face cover and other objects alike will block the reading capability.
  • Avoid direct sunlight.
  • Avoid high or low temperature background that could emit infrared particles – for example: kitchen cooking surface, heat, freezer/cooler, A/C unit.
  • Avoid direct/very close contact of heat generating object (area heater, TV) that could interfere with the temperature sensing. Use of low conducting material to block out the heat if necessary.

Temperature sensor calibration:

The temperature sensor is a very sensitive device. The calibration of the device will highly impact the ideal result. Device automatically calibrates to adopt different environment. Please follow the guideline below:

  • Device calibrates itself during the boot up process, please wait 10 minutes prior to use.
  • During the calibration time, the measurement result might not be correct.
  • If the device is moved, please wait at least 5 minutes so its self-calibration will adopt to the new environment.
  • Please avoid using the system rapidly or change of the environment during calibration. It is best to move the system after power off.

Setting up the temperature station:

Because of the temperature sensor uses 5 ~ 15 mm waves to detect the IR radiation from the object to determine temperature, which sunlight also contents the wave within this range which could interfere the reading. VA110 is not designed to operate outdoor out of the box. If outdoor application is necessary, please follow the important guidelines:

  1. Use tent to block sunlight and leave only the walk path open
  2. Avoid high wind, rain, and provide proper ventilation when environmental temperature is high.
  3. Use additional layer of background so we can avoid temperature sensor to measure the tent curtain itself. For example, a solid white board, plastic wall.
  4. To the best possible, have the tent inside temperature controlled between 15 C to 35 C. If a heater / air condition is needed, please avoid sending hot/cold air directly into the testing area.
  5. Device placement
    • Proper lighting to light up one (1) meter range at front of the camera.
    • Avoid back light and ensure tester’s face can be clearly seem.

Outdoor tent design example – use low conduct heat blocking material (yellow blocks)

Sunlight blocking heavy tent with proper air circulation

AtomOS Network Access Services and Ports

Boundary Service Source Destination Protocol DST Port Notes

WAN

IoT Service

AtomOS edge IoT client

AtomCloud IoT servers

TCP

8883

Required for Atomrock IoT service with MQTT over SSL

LAN (optional)

DHCP

DHCP client

DHCP Server

UDP

67

Optional for assigning network settings with DHCP clients

LAN/WAN

NTP

NTP Client

NTP Server

UDP

123

Required for time synchronization

LAN/WAN

DNS

DNS client

DNS Server

UDP

53

Required for clients to do domain name-to-IP address lookups

LAN

WS-Discovery

AtomOS WS-Discovery service

Multicast group at 239.255.255.250

UDP

3702

Required for Onvif discovery

LAN

Onvif

AtomOS ONVIF service

ONVIF camera

TCP

8000 (default)

Required for accessing Onvif service from end devices

LAN

RTSP

AtomOS streaming service

ONVIF camera

TCP/UDP

554 (default)

Required for obtain RTSP streaming access from Onvif client

WAN

HTTPS

AtomOS event agent

AtomCloud event servers

TCP

443

Required for sending event data to cloud

WAN

RTMPS

AtomOS event agent

AtomCloud event servers

TCP

443

Required for sending camera LIVE stream to cloud securely.

LAN (optional)

ICMP

Admin workstation

AtomOS device interface

ICMP

N.A.

For device tracking

LAN (optional)

Bonjour

AtomOS edge service advertising client

Multicast group at 224.0.0.251

UDP

5353

Advertise services using Bonjour protocol

LAN (optional)

SSH

Admin workstation

AtomOS device interface

TCP

21

Used for an admin to reach the AtomOS SSH setup interface

LAN (optional)

HTTP

Admin workstation

AtomOS device interface (AEC only)

TCP

8080

Used for an admin to reach the AtomOS web setup interface before it's connecting to cloud

WAN

RTMP over SSL

Live streaming service

AtomCloud Live streaming servers

TCP

443

Required for sending LIVE camera stream from AEC to cloud

FAQ

How do I correctly measure body temperature?

When measure skin surface on human face, it is best measured on the forehead. Because forehead has the advantages of large area, which also offer the most stable controlled temperature of the whole body. Aim forehead area into the temperature sensing range will provide the most accurate result.

How does the system mark the body temperature?

System registers body temperature at 0.1°C steps and update its matrix measurement every 0.25s. It has the following three categories: (numbers can be manually adjusted)

  • Normal: When normal body temperature is detected (35.8 °c to 37.5 °c)
  • Fever: When fever body temperature is detected (37.5 °c to 44 °c)
  • Too high: When abnormal high temperature is detected (44 °c and above)

What can I do if the temperature reading is not correct?

Temperature sensor works the best in a steady environment. In case of needing adjustment (i.e. height, different angles, move), please follow the guideline below:

  • When there is a change of environment (i.e. moving the device, sudden on/off the lighting in the room, change of large portion of the background), please wait 10 minutes before use. System will adjust itself to the new change automatically.
  • When first power up the device, please wait at 10 minutes before starting to use as the system calibrate itself.

How do I clean the temperature sensor?

Temperature reading can be affected when the lens is dirty, dusty or fogged. Avoid touching or have moister, water near the lens area. To clean it:

  1. Power off the entire system, wait for 30 seconds.
  2. Use alcohol based liquid on a soft-tissue fabric to wipe the temperature sensor’s lens, wait until the area is dry.
  3. Power on the system, and wait for 10 minutes for self-calibration.

How do I reset VA110 to factory default?

You can use the stand-alone setup menu to restore to factory default. If setup menu is not accessible (in cloud mode), you can connect USB keyboard, and press Ctrl key then R key together. System will prompt to enter text, then type in “resetfactory” and press enter. System will reset to factory default. Reset to factory default will not erase the cloud or stand-alone mode setting and its license.

How to Set the VA110 IP Address

You can configure the IP address for the VA110 using the following methods:

1. Using the Stand-Alone Setup Menu:

  • Access the stand-alone setup menu to configure IP address information directly.

2. Using a USB Keyboard (if the setup menu is not accessible, e.g., in cloud mode):

  • Connect a USB keyboard to the VA110.
  • Press the Ctrl key and the R key simultaneously.
  • The system will prompt you to enter a command.

To reset to the default IP address:

  • Type usedefaultip and press Enter.
  • The default IP settings will be:
  • IP Address: 192.168.80.80
  • Subnet Mask: 255.255.255.0
  • Default Gateway: 192.168.80.1
  • Primary DNS: 1.1.1.1
  • Secondary DNS: 8.8.8.8

To set a manual IP address:

  • Type the command:
    usemanualip 〈IP Address〉 〈Subnet Mask〉〈Default Gateway〉〈DNS Server〉
  • Replace 〈IP Address〉, 〈Subnet Mask〉, 〈Default Gateway〉, and 〈DNS Server〉with the desired values, separated by spaces.

To set a DHCP IP address:

  • Type the command:
    usedhcp